VXDIAG VCX SE Benz 2022.09 Xentry Initialization Multiplexer Failed Solution

Problem:

One of our customers got the VXDIAG VCX SE and 2022.09 Xentry HDD but it won’t connect to any Mercedes. Failed to communicate with 2005 w163, 2017 W205 and 2013 W212. Failed to read VIN or manual input along with error “initialization of the multiplexer has failed”. Any solution?

Vxdiag Benz 2022 09 Software Error 1 Vxdiag Benz 2022 09 Software Error 2

Solution:

He got technical help from vxdiagshop.com via Teamviewer.

He didn’t update the Benz C6 VCI driver.

Vxdiag Benz 2022 09 Software Error 3

Xentry 2022.09 requires the latest C6 driver upgrade.

VXDIAG Benz Update New VCI Driver for Xentry 2022.09

Do the following:

1. Update Benz C6 driver in vx manager
Vxdiag Benz 2022 09 Software Error 4

2.  Run Xentry recovery tool on the desktop to sync Xentry VCI.

Vxdiag Benz 2022 09 Software Error 5

NOTE: Don’t sync VCI before update C6 driver.  Always update C6 driver first.

 

3. Xentry 2022.09 is working fine. It will communicate with vehicle now.

Vxdiag Benz 2022 09 Software Error 6