VXDIAG ODIS Online Account Server Error ODS1003E Solution

Problem:

Trying to remove Component Protection (CP) and adapt a new key for a 2012 Audi A8L. Bought the VXDIAG VCX SE 6154 hardware with ODIS software and got a valid online account myself. However, when I attempt to log into my online account through ODIS, I get a server error. Has anyone encountered this and found a solution?

Error 1:

Fazil Service. ODS9220E.

 

VXDIAG ODIS Online Account ODS922E Server Error

Error 2: ODS1003E error.

VXDIAG ODIS Online Account ODS1003E Server Error

Solution:

For the error in image, make sure you get the correct online account name and token.

 

ODS1003E possible causes and solutions:

Cause 1
The security certificate was not imported to the application before PostSetup installation steps.

Resolve
Import the security certificate.

 

Cause 2
The certificate was revoked.
The wrong certificate was imported.

Resolve:
Verify you are using the correct certificate.

Cause 3
The dealership network is blocking the MirrorServer URL.

Resolve:
See your local network administrator. Ask them to verify that access to https://mirrorserver2.vwhub.com/dav/ is allowed.

 

Cause 4
The internet connection was interrupted during the update.

Resolve:

Hardwire the diagnostic device to the network and re-try the download.

www.vxdiagshop.com